Page 30 - Tohnichi_CIP
P. 30

Tohnichi Reference Guide 2019
            CNA-4mk3                             Assembly    Digital   Relay Counter  Judgment               RoHS


                       POKA Patrol/            ? Tightening count veri?cation with connecting up to 4 torque wrenches.
                                               ? Max. 8 preset counts, timer, alart by buzzer and lamp function are built in.
                       Count Checker           ? Ideal for manufactuaring process management of mixed production line.
                                                Count Display         16 × 32 dot-matrix LEDs
                                                                      30 × 25 square display lamp (commonly used for OK/NG)
                                                OK/NG Judgment Display  OK: Blue lamp turned on
                                                                      NG: Red lamp blinking + Buzzer sounds (4 patterns)
                                                Work No. Selection Display  1-digit 7-segment LED
                                                Count Input           Contact input × 4
                                                Max. Tightening Number of Bolts  99 counts
                                                Max. Number of Works  8 sets
                                                OK/NG Judgment Setting  ? Preset judgment, ? END input judgment, ? Automatic judgment (0 to 300 seconds in steps of 1 second)
                                                Output Function       ? OK/NG output (Relay contact output rating: 30 V DC, 1 A, 125 V AC, 0.3 A)
                                                                      ? Torque wrench selection signal output (Open collector rating: 100 mA)
                                                Input Function        ? SELECT input × 4, ? START input, ? END input, ? RESET input, ? WORK SENSOR input
                                                                      ? Double count prevention timer (0 to 10 seconds in steps of 0.1 second)
                                                Timer Function Setting  ? Automatic reset timer (0 to 60 seconds in steps of 1 second)
                                                                      ? Interval warning timer (0 to 99 seconds in steps of 1 second)
                                                Setting Method        Special-purpose application software (USB communication), key operation
                                                Operating Condition   0 ~ 40 °C, Below 85%RH (no condensation)
                   CNA-4mk3                     Power Supply/Electricity Consumption  AC100 ~ 240V ± 10% 50/60Hz, Below 10W
     Torque Wrench for   Assembly  CNA-4mk3 Outline  Add the Count Checker to complete your torque verification system,
                                                                      400g, W121 × D175 × H44.9mm
                                                Weight/Dimension
                                               Standard Accessories Connecting cable (CNA-4mk3 to PC, USB A-B type)
                                               to visualize and track clicks captured from a variety of compatible Tohnichi models.
                                               Compatible Models
                                                           ?  LS/MS Limit Switch Wrenches.
                                                           ?  Wrenches & Receivers Models Series: FH, FHSLS, FHP, FHD, FD/FDD, BLA, BLE and FMA

                                                       Setting example
                                                       Connect 2 LS torque wrenches directly and 2 Wireless torque wrench
                                                       through receiver and I/O box.
                   Wrench No. 1   Wrench No. 2   Wrench No. 3     Wrench No. 4
                                                       Work No.2 is required to tighten 2 different portions, one has hexagon bolts

               Work                                    4pcs and the other has cap screw 3pcs
               No. 1

               Work                                     No.             Setting             WRENCH No.1   WRENCH No.2   WRENCH No.3   WRENCH No.4
               No. 2
                                                        2       Tightening count                4                         0                          3                          0  ?
                                                                               ?
                                                                                                   ?
                                                                                         ?

               Work                                                      1            4
               No. 3                                                                        1       3       2
                                                                         3            2
               Up to
               Work
               No. 8                                   Set the number of bolts (0-99pcs) the work needs for each torque
                                                       wrench. Set 0 when no torque wrench is needed.
              Example of Various Timer Functions
              Automatic Judgment Timer (1-300 sec. 1 sec. interval)   Interval Timer (0-99 sec. 1 sec. interval)
              Starts after START input or input of first count signal, and judges   If the operator does not go on to the next bolt within the interval
              OK/NG as the timer reaches set time               timer (0-99 sec. 1 sec. interval), the alarm goes off to warn the
                                                                operator.
              [Timing chart]                                    [Timing chart]
               Tightening number 3pcs, Judgment mode JG3, Automatic judgment timer 6sec.  Tightening number 4pcs, Interval timer 5 sec.

                Count display  ?3?  ?2?  ?1?
              Count signal input                                Count signal output
               START input                                                                 5 sec.
                                          6 sec.                Interval timer  5 sec. pass  within  5 sec. pass
              OK / NG output
                                                       NG       Warning alert        Sound               Sound
              Judgment output
                                                                                  PPP                 PPP
                                                                                    ...                 ...
              Double count prevention (0.1-10 sec. 0.1 sec. interval)   Easy setting with CNA-4mk3 setting software
              Prevents counting an accidental double click      Setting software gives instruction for each setting parameter.
              [Timing chart]
               Tightening number 3pcs, set on 0.5 sec.
               and operates torque wrench several times within 0.5 sec.
                Count display  ?3? ?2?    ?1?           ?0?
              Count signal input
               Effective count
              Double count      0.5 sec.     0.5 sec.
              prevention timer




    27
   25   26   27   28   29   30   31   32   33   34   35